Telerehabilitation, a specialized domain within telemedicine, supports remote physical rehabilitation and progress monitoring. Wearable sensors can improve this service by providing reliable monitoring of movement parameters, offering objective information into patients’ rehabilitation sessions. This study presents the development and validation of a telerehabilitation system including a rehabilitation protocol, low-cost wearable inertial measurement units (IMUs) and a set of metrics descriptive of movement capacity to analyze rehabilitation exercises. Eleven medically stable elders (9 females, 2 males; age: 72.6 ± 5.0 years; height: 1.66 ± 0.09 m; mass: 67.8 ± 9.8 kg) performed 12 rehabilitation upper/lower limb and trunk exercises. Movement analysis was conducted using a prototypical IMU sensor and commercially available IMU as a reference. Each exercise was automatically segmented into single repetitions, from which selected metrics were computed. Bland–Altman analysis was performed to evaluate measurement agreement and consistency between the systems across all parameters. Results indicate acceptable measurement agreement for key rehabilitation metrics, including movement quantity, accelerations intensity, and movement smoothness. However, angular velocity and movement stability reveal technical limitations requiring refinement prior to clinical implementation. Balancing measurement reliability and affordability of telerehabilitation system remains a crucial factor to offer an effective service to individuals with diverse health conditions.

Validation of Low-Cost IMUs for Telerehabilitation Exercises

Caramia, Federico
Investigation
;
Lucangeli, Leandro
Formal Analysis
;
Camomilla, Valentina
Supervision
2025-01-01

Abstract

Telerehabilitation, a specialized domain within telemedicine, supports remote physical rehabilitation and progress monitoring. Wearable sensors can improve this service by providing reliable monitoring of movement parameters, offering objective information into patients’ rehabilitation sessions. This study presents the development and validation of a telerehabilitation system including a rehabilitation protocol, low-cost wearable inertial measurement units (IMUs) and a set of metrics descriptive of movement capacity to analyze rehabilitation exercises. Eleven medically stable elders (9 females, 2 males; age: 72.6 ± 5.0 years; height: 1.66 ± 0.09 m; mass: 67.8 ± 9.8 kg) performed 12 rehabilitation upper/lower limb and trunk exercises. Movement analysis was conducted using a prototypical IMU sensor and commercially available IMU as a reference. Each exercise was automatically segmented into single repetitions, from which selected metrics were computed. Bland–Altman analysis was performed to evaluate measurement agreement and consistency between the systems across all parameters. Results indicate acceptable measurement agreement for key rehabilitation metrics, including movement quantity, accelerations intensity, and movement smoothness. However, angular velocity and movement stability reveal technical limitations requiring refinement prior to clinical implementation. Balancing measurement reliability and affordability of telerehabilitation system remains a crucial factor to offer an effective service to individuals with diverse health conditions.
2025
IoT
inertial sensors
movement intensity
movement quality
physical exercises
telemedicine
File in questo prodotto:
File Dimensione Formato  
sensors-25-03129.pdf

accesso aperto

Descrizione: Article
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 3.48 MB
Formato Adobe PDF
3.48 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14244/10624
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
social impact